Information Name: | BS standard wire and cable burning rain shock and vibration testing machine parameters and image |
Published: | 2015-05-19 |
Validity: | 360 |
Specifications: | MU3160 |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | MU3160 BS shock and vibration performance wire and cable combustion testing machine The test machine, including the fire resistance test, water spray fire resistance test and mechanical fire resistance test, for rated voltage not exceeding 450 / 750V mineral insulated cables, for a long time under fire conditions hold circuit intact. Compliance with a British Standard fire-resistant cables BS6387 "hold circuit integrity in case of fire cable performance requirements specification." 1. The fire resistance test: fire resistance test station includes the following sections 1.1: Cable Support System 1.2: continuous detection means 1.3: Heat cable support systems: cable clamped by a clip lateral ends of the cable sheath. The middle part of the cable is composed of two metal rings (separation distance 300mm) fixed, other metal parts of grounded metal ring with the device. For a diameter less than 10mm unarmoured cable, or some other obvious displacement during the test cable for three metal rings, each fixed in the original metal ring at approximately 150mm. Continuous detection devices: the test current through all core cables, a three-phase star connected transformer or three single-phase transformers (or a single-phase transformer, if the test for the single-core cable), and have sufficient capacity to maintain the maximum allowable leakage current of 3A at the test voltage. At the other end of the cable to connect each wire a lamp, and at the rated voltage cables close 0.25A load current 1.3.1: Heat is a 610 mm long can be forced supply of methane flame dense tubular gas burners . 1.3.2: Temperature Measurement: diameter of 2mm armored thermometer placed near the inlet, parallel to the burner 75mm above 1.3.3: test flame temperature and time :( see BS6387 flame rating) A 650. C ± 40 ° C -3 hours B 750. C ± 40 ° C -3 hours C 950. C ± 40 ° C -3 hours S 950. C ± 40 ° C -20 minutes 1.3.4: Sample: the sample is finished in a period of not less than 1200mm, both ends of the sheath is removed and the cover layer of 100mm. The wire ends of the cable should be in accordance with the electrical connection. Second, water fire test include the following: 2.1: 2.2 cable support systems: continuous detection means 2.3: Heat cable support systems: cable connection in two rigid plates 25mm wide metal stents, stents with metal clips Figure II pitch clip is 200mm. Cables attached to the bracket shown in Figure 2. All the metal frame grounding. Continuous detection means: in the test current through all core cables, three single-phase transformers, and has sufficient capacity is maintained at the test voltage reaches the maximum allowable leakage current is 3A. At the other end of the cable to connect each wire a lamp, and close 0.25A load current at the rated voltage cable. 2.3.1: Heat: A strip of burner can burn to a length of 400mm 400mm of cable sample. Burner assembly can be adjusted to provide a bright flame temperature of 650 ± 40 ° C, 2.3.2: temperature measurement: diameter of 2mm armored thermometer placed under the surface of the cable 2.3.3: test flame temperature: 650 . C ± 40 ° C 2.3.4: water: a nozzle mounted on a test stand, in the middle of the burner to pressure 250KPa 350KPa, in the vicinity of the sample spray 0.25 liters to 0.30 liters per square meter per square meter. water. This rate requires measurement with a collection tray, this disk has enough depth to make his major axis parallel to the axis of the cable and centered. This tray about 100mm wide and 400mm long. 2.3.5: Sample: Sample is greater than 1500mm from the finished product, and the bending test has been done at ambient temperature, both ends of the cover layer is removed and the sheath of 100mm. At both ends of the cable wires and electrical connections should be in accordance with the manufacturer's recommendations for proper disposal 2.3.6: test voltage: 200 ~ 1000V adjustable Third, resistance to mechanical shock and fire: the test device shown in the following sections, the assembly is secured in slotted frame corresponding position. 3.1 cable fixed on one side of a vertical wall, heat-resistant non-combustible material is fixed to the plate; 3.2 transformer fuse connection with lights to indicate the circuit is a continuous wall heat 3.4 3.3 shock device and its installation wall is made of a heat barrier burning material and fixed on the two horizontal beams, one in the upper plate and the other one in the bottom plate. This board about length 900mm, width 300 mm, thickness of 9 mm, and the total weight of the wall (ie panels plus support frame) was 10 ± 2 kg .. Each girder is about 1m, 25mm square steel tube. If you need a filler material, you need to place it inside the steel beams. Steel beams must be fixed in the upper plate, so the upper edge is flush with the upper surface and the plate. Steel beams and the outer edge of each plate has a horizontal hole, its exact location is determined by the needs of specific support pad and support frame. 4 by a rubber bushing wall bonded to the frame, the bushing diameter of approximately 32mm thick 20mm. Continuous detection means: in the test current through all core cables, three single-phase transformers, and has sufficient capacity is maintained at the test voltage reaches the maximum allowable leakage current is 3A. At the other end of the cable to connect each wire a lamp, and close 0.25A load current at the rated voltage cable. 3.4.1: Heat: A strip of burner can burn to a length of 400mm 400mm of cable sample. Burner assembly can be adjusted to provide a bright flame temperature of 650 ° C, 3.4.2: temperature measurement: diameter of 2mm armored thermometer thermometer thermometer at a distance through the wall is the wall 8mm to 10mm. Temperature measured by the following procedure: In the end of the mild steel rod diameter 3mm ± 5% Length 300mm tied a thermometer, so that it can measure the temperature of the rod. Grab it with the stick close to the flame from the flame is maintained at 40mm to 50mm. The temperature when the flame temperature of 950 ° C, the steel bar in the 10s to 20s temperatures can reach 400 ° C, when the flame temperature of 650 ° C, the temperature in the 20s to 40s rod can reach 400 ° C. 3.3.3 : test flame temperature and time: the test temperature required to select from the table below: X 650 ± 40 ° CY 750 ± 40 ° CZ 950 ± 40 ° C 3.4.4: vibration means vibration device consists of a mild steel bar (diameter 25mm ± 5%, long 600mm ± 5%). The rod longitudinal plane parallel to the wall, higher than the top of the wall 200mm. A shaft 200mm and 400mm will be divided into two parts, the long portion toward the wall. Separated by 30 ± 2S dropped from 60 ° C from a parallel position to the wall of the middle position. 3.4.5: Sample: Sample is a cable in a period of not less than 1200mm, both ends of the sheath is removed and the cover layer of 100mm. At both ends of the cable wires shall make appropriate preparations in accordance with the electrical connection to the manufacturer's recommendations. Cable needs to bend from the middle into two nearly equal length, parallel section. The diameter of the curved portion 6D, D represents the outer diameter of the cable. The cable into a Z-shape, fixed at both ends of the horizontal distance 13D. Copper cable clip needs fixed to the wall, install special cables need to consult the manufacturer. Clip needs to be fixed in the two curved portions of the cable, the curved intermediate portion is vertical: horizontal cable becomes part of the adjacent clip equidistant about 150mm to 200mm 3.4.6: Test Voltage: 200 ~ 1000V adjustable horizontal Combustion test: A level of 650 ℃ / 3h, grade B 750 ℃ ??/ 3h, C-class 950 ℃ / 3h and S-class 950 ℃ / 3min. A class represents the voltage level of 300 volts is applied burning three hours without breakdown at 650 ℃; grade B indicates the voltage level of 300 volts is applied burning three hours without breakdown at 750 ℃; C level indicates the voltage level of 300 volts is applied at 950 ℃ burning three hours without breakdown; S-class represents the voltage level of 300 volts is applied at 950 ℃ burn 3 minutes without breakdown. Water spray burning test: is divided into W, which indicates that in applying 300 volts burn 15 minutes and then 15 minutes water spray combustion without breakdown. First, the service commitment 1, Quality Assurance: As equipment suppliers King Industrial Co., Ltd. Shanghai Mu. My company to this tender provided products are factory original packaging, in line with the family of quality certification and quality certification system, and provide technical information (including installation instructions, product packing catalogs mouth Chinese manual, qualified and a warranty certificate, etc.). 2, supply and installation time: after payment is received in contract to provide goods to customers. Product manufacturing and testing are quality records and inspection data. On product performance testing, we have the product of the whole process, all performance checks, was confirmed to be qualified before packing shipments. 3. Product delivery: as requested by the user, if you have special requirements, be completed ahead of schedule, I may in particular organization of production, installation, and strive to meet customer needs. 4, Warranty: All product shelf life within our supply agreement is valid for this offer, all products offered within the validity period, provided normal working day services, lifetime technical support services. 5. Response time: seven working days in the event of quality problems or cause inconvenience to the impact on the operation of the user, the company promised within three working days of the devices for a free replacement. The warranty period, the product if a fault occurs, the Company received after repair, if necessary, our company will provide alternative facilities. Performance due to equipment failure during the warranty period repair two still can not normally use our free replacement of new equipment. 6, the service system: the company as a supplier of equipment for the tender offer products provide security system: When equipment fails, if necessary, will send designated professional technicians within the specified time home repair or send repair, buyer fee willing to produce the transport fees paid by the Company. |
Admin>>>
You are the 19300 visitor
Copyright ©2025 GuangDong ICP No. 10089450, Instrument Co., Ltd. Shanghai Jing Mu All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 19300 visitor
Copyright ©2025 GuangDong ICP No. 10089450, Instrument Co., Ltd. Shanghai Jing Mu All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility